Honda Fit manuals

Honda Fit: Torque Converter Housing Lubrication Check Valve Replacement (A/T)

Second generation (2007-2025) / Honda Fit 2007-2025 Repair Manual / Powertrain / Transmission/Transaxle / Automatic / Torque Converter / Torque Converter Housing Lubrication Check Valve Replacement (A/T)

  1. Remove the sealing bolt (A) and the sealing washer (B).

  1. Remove the lubrication check valve (C) from the torque converter housing (D).

  2. Install the lubrication check valve, a new sealing washer, and the sealing bolt.

See also:

Transmission End Cover Removal (A/T)
Special Tools Required Mainshaft Holder 07GAB-PF50101 Remove the bolts securing the ATF inlet line (D) and ATF filter holder (E), the line bolt and sealing washers, and remove the ATF in ...

Air Cleaner Removal/Installation
Disconnect the MAF sensor/IAT sensor connector(A), then remove the air cleaner cover (B) and the air cleaner element (C). NOTE: Be careful not to damage the MAF sensor/IAT sensor on the air ...

Gauge Control Module Replacement
NOTE: Before replacing the gauge control module, retrieve the ODO value and the maintenance minder information from the gauge control module with the HDS. Remove the instrument panel. ...

© 2025 Copyright www.hfitinfo.com