  1. Remove the sealing bolt (A) and the sealing washer (B).

  1. Remove the lubrication check valve (C) from the torque converter housing (D).

  2. Install the lubrication check valve, a new sealing washer, and the sealing bolt.

See also:

Warm Up TWC Removal/Installation
NOTE: If the warm up TWC is damaged internally, inspect the under-floor TWC for debris. Raise the vehicle on a lift. Remove the bolts (A). Lower the vehicle. ...

Secondary Shaft 2nd Gear Axial Clearance Inspection (A/T)
Install the thrust needle bearing (A), the needle bearing (B), 2nd gear (C), the thrust needle bearing (D), the 43 x 54.5 mm thrust washer (E), the 39 mm cotters (F), and the cotter retain ...