Honda Fit: Torque Converter Housing Lubrication Check Valve Replacement (A/T)

Second generation (2007-2026) / Honda Fit 2007-2026 Repair Manual / Powertrain / Transmission/Transaxle / Automatic / Torque Converter / Torque Converter Housing Lubrication Check Valve Replacement (A/T)

  1. Remove the sealing bolt (A) and the sealing washer (B).

  1. Remove the lubrication check valve (C) from the torque converter housing (D).

  2. Install the lubrication check valve, a new sealing washer, and the sealing bolt.

See also:

Cylinder Head Inspection for Warpage
Remove the cylinder head. Inspect the camshaft. Check the cylinder head for warpage. Measure along the edges, and three ways across the center: If wa ...

Transmission End Cover ATF Feed Pipe Replacement (A/T)
Remove the snap ring (A), the 3rd clutch feed pipe (B), and the feed pipe flange (C) from the end cover (D). Install a new O-ring (E) over the 3rd clutch feed pipe. In ...