Remove the harness holder (A).

Disconnect the hose (A).

Remove the PCV valve (B).
Install the parts in the reverse order of removal with a new 14 mm washer (C).
Breather Line and Suction Line Inspection (Page-1)
Special Tools Required
Fuel Pressure Gauge Attachment Set 07AAJ-S6MA150
Vacuum Pump/Gauge, 0-30 inHg Snap-on YA4000A or equivalent, commercially
available
Vacuum/Pressure Gauge, 0-4 inHg 07 ...
Torque Converter Housing Lubrication Check Valve Replacement (A/T)
Remove the sealing bolt (A) and the sealing washer (B).
Remove the lubrication check valve (C) from the torque converter housing
(D).
Install the lubrication check val ...
Mainshaft Bearing and Oil Seal Replacement (M/T)
Special Tools Required
Driver Handle, 15 x 135L 07749-0010000
Bearing Driver Attachment, 37 x 40 mm 07746-0010200
Bearing Driver Attachment, 52 x 55 mm 07746-0010400
Adjustable Bearing Puller, ...