Connecting Rod Bolt Inspection
Measure the diameter of each connecting rod bolt at point A and point B
with a micrometer.
Calculate the difference in diameter between point A and point B.
Point AпјЌPoi ...
M/T Differential Thrust Clearance Adjustment (M/T)
Special Tools Required
Driver Handle, 40 mm I.D. 07746-0030100
Remove the left driveshaft side oil seal from the transmission housing.