Honda Fit manuals

Honda Fit: Torque Converter Housing Selector Control Shaft Oil Seal Replacement (A/T)

Second generation (2007-2026) / Honda Fit 2007-2026 Repair Manual / Powertrain / Transmission/Transaxle / Automatic / Torque Converter / Torque Converter Housing Selector Control Shaft Oil Seal Replacement (A/T)

Special Tools Required

  1. Remove the oil seal from the torque converter housing.

  1. Install the new oil seal (A) in the torque converter housing to a depth (B) of 0.5пјЌ1.5 mm (0.02пјЌ0.06 in)   below the housing surface using the driver handle and the oil seal driver attachment.

See also:

A/T System Description - Lock-Up System (A/T)
Lock-up SystemThe lock-up mechanism of the torque converter clutch operates in all five gears in D, in 3rd gear in D3, and 3rd and 4th gears in S with the automatic shift mode. The pressurize ...

Online Reference Owner's Manual
This owner’s manual should be considered a permanent part of the vehicle and should remain with the vehicle when it is sold. This owner’s manual covers all models of your vehicle. You may find ...

Drive Belt Inspection
Inspect the belt for cracks or damage. If the belt is cracked or damaged, replace it. Check that the position of the auto-tensioner indicator (A) is within the standard range ( ...