Honda Fit manuals

Honda Fit: Torque Converter Housing Selector Control Shaft Oil Seal Replacement (A/T)

Second generation (2007-2026) / Honda Fit 2007-2026 Repair Manual / Powertrain / Transmission/Transaxle / Automatic / Torque Converter / Torque Converter Housing Selector Control Shaft Oil Seal Replacement (A/T)

Special Tools Required

  1. Remove the oil seal from the torque converter housing.

  1. Install the new oil seal (A) in the torque converter housing to a depth (B) of 0.5пјЌ1.5 mm (0.02пјЌ0.06 in)   below the housing surface using the driver handle and the oil seal driver attachment.

See also:

Overheating
How to Handle Overheating Overheating symptoms are as follows: • The high temperature indicator comes on or the engine suddenly loses power. • Steam or spray comes out of the engine compartment ...

Cylinder Head Inspection for Warpage
Remove the cylinder head. Inspect the camshaft. Check the cylinder head for warpage. Measure along the edges, and three ways across the center: If wa ...