Remove the valves.
Measure the valve in these areas.
Intake Valve Dimensions
|
A Standard (New): |
27.85пјЌ28.15 mm (1.0965пјЌ1.1083 in) |
|
B Standard (New): |
118.55пјЌ119.15 mm (4.6673пјЌ4.6909 in) |
|
C Standard (New): |
5.48пјЌ5.49 mm (0.2157пјЌ0.2161 in) |
|
C Service Limit: |
5.45 mm (0.2146 in) |
Exhaust Valve Dimensions
|
A Standard (New): |
22.85пјЌ23.15 mm (0.8996пјЌ0.9114 in) |
|
B Standard (New): |
117.25пјЌ117.85 mm (4.6161пјЌ4.6398 in) |
|
C Standard (New): |
5.45пјЌ5.46 mm (0.2146пјЌ0.2150 in) |
|
C Service Limit: |
5.42 mm (0.2134 in) |

Intermediate Shaft Removal (A/T)
Drain the transmission fluid. Reinstall the drain plug with a new sealing
washer.
Remove the right driveshaft.
Remove the shift cable cover (A).
Re ...
Tool Maintenance
Follow these instructions to keep the ATF cooler cleaner working properly:
Replace the two magnetic nonbypass spin-on filters after every 20 hours
of use, based on the hour meter, or when yo ...
Stator Test
Check that there is continuity between each lead (A):
If there is continuity, go to step
24.
If there is no continuity, replace the stator.
...