Remove the valves.
Measure the valve in these areas.
Intake Valve Dimensions
|
A Standard (New): |
27.85пјЌ28.15 mm (1.0965пјЌ1.1083 in) |
|
B Standard (New): |
118.55пјЌ119.15 mm (4.6673пјЌ4.6909 in) |
|
C Standard (New): |
5.48пјЌ5.49 mm (0.2157пјЌ0.2161 in) |
|
C Service Limit: |
5.45 mm (0.2146 in) |
Exhaust Valve Dimensions
|
A Standard (New): |
22.85пјЌ23.15 mm (0.8996пјЌ0.9114 in) |
|
B Standard (New): |
117.25пјЌ117.85 mm (4.6161пјЌ4.6398 in) |
|
C Standard (New): |
5.45пјЌ5.46 mm (0.2146пјЌ0.2150 in) |
|
C Service Limit: |
5.42 mm (0.2134 in) |

Interior Lights
Interior Light Switch
■ ON
The interior light comes on regardless of
whether the doors are open or closed.
■ Door activated
The interior light comes on in the following
situation ...
Breather Line and Suction Line Inspection (Page-2)
Attach the fuel pressure gauge attachment. Then connect the vacuum pump/gauge
(A) to the suction line (B), and apply vacuum to the line:
If the line holds vacuum, check for a blocka ...
TPMS System Description (USA models)
TPMS Control Unit Inputs and Outputs at the
20P Connector