Tool Maintenance
Follow these instructions to keep the ATF cooler cleaner working properly:
Replace the two magnetic nonbypass spin-on filters after every 20 hours
of use, based on the hour meter, or when yo ...
Valve Stem-to-Guide Clearance Inspection
Remove the valves.
Subtract the O.D. of the valve stem, measured with a micrometer, from the
I.D. of the valve guide, measured with an inside micrometer or ball gauge.
Take t ...
Reassembly
Install the upper spring seat (A) to the upper spring seat clip (B).
NOTE: Make sure to securely set the upper spring seat to the hook (C) on
the spring seat clip.
...