Removal (Part -3)
Remove the secondary HO2S harness bracket (A) from the steering gearbox.
NOTE: Do not disconnect the secondary HO2S 4P connector and the secondary HO2S.
...
Breather Line and Suction Line Inspection (Page-1)
Special Tools Required
Fuel Pressure Gauge Attachment Set 07AAJ-S6MA150
Vacuum Pump/Gauge, 0-30 inHg Snap-on YA4000A or equivalent, commercially
available
Vacuum/Pressure Gauge, 0-4 inHg 07 ...
Valve Stem-to-Guide Clearance Inspection
Remove the valves.
Subtract the O.D. of the valve stem, measured with a micrometer, from the
I.D. of the valve guide, measured with an inside micrometer or ball gauge.
Take t ...