Honda Fit manuals

Honda Fit: Rectifier Test

  1. Check for continuity in each direction, between the B terminal and P terminals, and between the E terminal and P terminals of each diode pair. All diodes should have continuity in only one direction. Because the rectifier diodes are designed to allow current to pass in one direction, and the rectifier is made up of six diodes (six pairs), you must test each diode in both directions for continuity with an ohmmeter that has diode checking capability: a total of 24 checks:

    • If any diode failed, replace the rectifier assembly. (Diodes are not available separately.)

    • If all the diodes are OK, go to step 19.

  2. BP1EP2P3P4P5P6Stator sideRear housing side
    BP1EP2P3P4P5P6
See also:

Ignition Switch Replacement
NOTE: SRS components are located in the area. Review the SRS component locations, and precautions and procedures   before doing repairs or servicing. Do the battery terminal di ...

Brake/Clutch Fluid
Specified fluid: Honda Heavy Duty Brake Fluid DOT 3 Use the same fluid for both the brakes and clutch. NOTICE Brake fluid marked DOT 5 is not compatible with your vehicle’s braking system and ca ...

Driving with the Paddle Shifters (Sport only)
Using the Paddle Shifters in D position (D-Paddle Shift Mode) When you are driving in D position, you can shift the transmission up or down manually with the paddle shifters. To shift up or down ...