Honda Fit: Door Glass Adjustment

NOTE: Check the weatherstrips and glass run channel for damage or deterioration, and replace them if necessary.

  1. Place the vehicle on a firm, level surface.

  1. Remove these items:

    • Door panel:

      • Front door

      • Rear door

    • Plastic cover:

      • Front door

      • Rear door

  1. Carefully move the glass (A) until you can see the glass mounting bolts (B), then loosen them.

  2. Front door

    CAB6 x 1.0 mm9.8 Nح(1.0 kgfح, 7.2 lbfئt)

    Rear door

    CAB6 x 1.0 mm9.8 Nح(1.0 kgfح,7.2 lbfئt)
  3. Push the glass against the channel (C), then tighten the glass mounting bolts.

  4. Check that the glass moves smoothly.

  1. Raise the glass fully, and check for gaps. Also check that the glass (A) contacts the glass run channel (B) evenly.

  2. BA
  3. Attach the plastic cover, making sure it is sealed around its outside perimeter to seal out water.

  1. Check for water leaks. Run water over the roof and on the sealing area as shown, and note these items:

    • Use a 12 mm (1/2 in) diameter hose (A).

    • Adjust the rate of water flow as shown (B).

    • Do not use a nozzle.

    • Hold the hose about 300 mm (12 in) away from the door (C).

  2. 12 mm (1/2 in)0.5 m (19 in)300 mm (12 in)ABC
  3. Reinstall the door panel:

    • Front door

    • Rear door

  4. Driver's door: Do the power window control unit reset procedure.

See also:

Recirculation Control Cable Adjustment
Open the glove box. Release the glove box stop on each side, then let the glove box hang down. Set the recirculation control lever to FRESH (). Detach the recirculation ...

Rear Defogger/Heated Door Mirror* Button
Press the rear defogger and heated door mirror button to defog the rear window and mirrors when the ignition switch is in ON . NOTICE When cleaning the inside of the rear window, be careful no ...

Spark Plug Inspection
Remove the ignition coils and the spark plugs. Inspect the electrodes and the ceramic insulator: Burned or worn electrodes may be caused by these conditions: ...